Donaldson® Ultracool Mini Series Process Water Chiller
• UC-0010 – UC-0240
• 2,000 Btu/h – 92,000 Btu/h
Due to the compact design of the Donaldson® Ultracool Mini Series Process Water Chiller, it is ideal for suiting decentral cooling of machinery and processes. The Ultracool Mini is easy to use and maintain and has easy access to all movable parts and has a very low sound level.
Features and Benefits
Donaldson® Ultracool Mini
Process Water Chiller
- Environmentally friendly refrigerant R-134a, allows ambient temperatures up to 122°F
- Models UC-0010 – UC 0240 SP cover nine units with cooling performances between ¼ and 10 ton
- Can be mounted on wheels, which enables chilling at the point, either central or decentral
- Housings in galvanized steel and externally coated with epoxy resin
- Evaporator in stainless steel AISI 316L, water pipes of PE
- Protection degree: IP54 from UC-0060 SP
- Antifreeze thermostat
- Thermal flow switch
- Refrigerant pressure gauges from UC 0100 SP
- Oversized condenser
- Large polyethylene cold water tank
- Level switch and level indicator
- Pump: impeller, intermediate chambers and shaft in stainless steel
- Internal calibrated by-pass
UC Water Chiller Options
- Auto-filling kit
- External alarm contacts (standard on Midi)
- External bypass
- Fan motor speed regulator
- Water flow meter
- Water heaters
- Water temperature stability kit
- Water pump: 70 psig and/or stainless steel
- Wheels (available on Mini only)
- Water-cooled condenser
|
Model UC Mini |
Cooling Capacity1 |
Water Flow |
Connection NPT |
Water Pressure |
kW |
FLA |
Voltage |
Dimensions (inches) |
Weight |
| ton |
BTU/Hr |
GPM |
inches |
40 psi |
70 psi |
SP 40 psi |
SP 70 psi |
SP 40 psi |
SP 70 psi |
Standard |
Height |
Width |
Depth |
(lbs) |
| UC-0010 SP |
0.23 |
2853 |
0.44 |
3/8 |
48 |
- |
1.20 |
- |
9.3 |
- |
230-1-60 |
27 |
20 |
16 |
132 |
| UC-0020 SP |
0.45 |
5443 |
0.85 |
1/2 |
48 |
75 |
1.69 |
1.99 |
13.7 |
16.9 |
230-1-60 |
35 |
21 |
25 |
254 |
| UC-0040 SP |
1.33 |
15,894 |
2.47 |
1/2 |
46 |
73 |
2.22 |
2.52 |
20.8 |
24.0 |
230-1-60 |
44 |
23 |
28 |
276 |
| UC-0060 SP |
2.54 |
30,431 |
4.73 |
3/4 |
51 |
70 |
4.17 |
4.33 |
12.4 |
12.9 |
460-3-60 |
45 |
31 |
35 |
408 |
| UC-0080 SP |
3.09 |
37,018 |
5.75 |
3/4 |
49 |
68 |
4.63 |
4.79 |
14.4 |
14.9 |
460-3-60 |
45 |
31 |
35 |
441 |
| UC-0100 SP |
4.12 |
49,447 |
7.68 |
1 |
45 |
78 |
5.66 |
5.88 |
17.8 |
18.4 |
460-3-60 |
49 |
33 |
39 |
518 |
| UC-0140 SP |
5.19 |
62,181 |
9.66 |
1 |
42 |
70 |
6.81 |
7.03 |
25.8 |
26.4 |
460-3-60 |
49 |
33 |
39 |
573 |
| UC-0180 SP |
7.13 |
85,629 |
13.30 |
1 |
44 |
67 |
8.54 |
8.90 |
31.0 |
31.6 |
460-3-60 |
64 |
37 |
45 |
827 |
| UC-0240 SP |
9.90 |
118,829 |
18.46 |
1 |
41 |
68 |
11.77 |
12.60 |
40.5 |
41.6 |
460-3-60 |
64 |
37 |
45 |
882 |
| |
| 1 Cooling Capacity refers to 50-degrees Fahrenheit water outlet temperature and 77-degrees Fahrenheit ambient temperature. |
| Mini series is equipped with refrigerant R-134a; maximum ambient temperature 122-degrees Fahrenheit. |
Capacity Correction Factors Ultracool Process Water Chillers (Mini & Midi)
| Capacity Correction Factors - Ambient Temperature (C1) |
| Ambient Temperature (degrees Fahrenheit) |
77 |
85 |
95 |
105 |
115* |
122* |
| Correction Factor |
1.0 |
0.9 |
0.8 |
0.78 |
0.72 |
0.66 |
| Capacity Correction Factors - Water Outlet Temperature (C2) |
| Water Outlet Temperature (degrees Fahrenheit) |
|
23 |
35 |
44 |
50 |
55 |
65 |
| Correction Factor |
0.38 |
0.54 |
0.83 |
1.0 |
1.1 |
1.25 |
| * Applies to models UC-0010 SP - UC-0240 SP |
| To calculate the capacity of a given process water chiller based on non-standard operating conditions, multiply the standard capacity by the appropriate correction factor(s). |
| EXAMPLE: |
Chiller Model: |
UC-100 SP |
|
|
| |
Standard Capacity: |
4.12 ton |
|
|
| |
Actual Operating Conditions: |
85-degrees Fahrenheit ambient temperature C1=0.5 |
| |
|
|
44-degree water outlet temperature C2=0.83 |
| Adjusted Capacity = 4.1 ton x 0.9 x 0.83 = 3.08 ton |
|
|
| To choose a process water chiller based on a given capacity at non-standard operating conditions, divide the given capacity by the appropriate correction factor(s). |
| EXAMPLE: |
Given Capacity: |
7.5 ton |
|
|
| |
Actual Operating Conditions: |
77-degrees Fahrenheit ambient temperature C1=1.0 |
| |
|
|
55-degree water outlet temperature C2 = 1.1 |
| Adjusted Capacity = 7.5 ton/1.0/1.1 = 6.82 ton |
|
|
|
| Selected Chiller Mode: UC-0180SP |
|
|
|
|
For more information on the Donaldson® Ultracool Mini Series Process Water Chillers
or any other Donaldson® product: Call 1-800-764-9793 or use our Contact Form.